BTZNQ - DOCUCOPY 1400 DEVELOPER, PT1

  • MSDS: BTZNQ
  • Manufacturer: SOLUTEK CORP
  • Product Name: DOCUCOPY 1400 DEVELOPER, PT1
  • National Stock Number: 6750-00N051207
Product Identification

Product ID:DOCUCOPY 1400 DEVELOPER, PT1
MSDS Date:05/11/1989
FSC:6750
NIIN:00N051207
Kit Part:Y
MSDS Number: BTZNQ

Responsible Party
SOLUTEK CORP
2865 METROPOLITAN PLACE
POMONA, CA 91767
US

Emergency Phone: 617-445-5335

Info Phone: 617-445-5335

Cage: 20536

Contractor
SOLUTEK CORP
BOSTON, MA 02119-3036 US

Cage: 20536

Ingredients

HYDROQUINONE (SARA III)

CAS: 123-31-9

RTECS: MX3500000

Fraction By Weight: <10%

OSHA PEL 2 MG/M3

ACGIH TLV: 2 MG/M3

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


POTASSIUM HYDROXIDE (SARA III)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: <15%

OSHA PEL 2 MG/M3, C

ACGIH TLV: 2 MG/M3, C

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IRRITATION OF EYES, SKIN, RESPIRATORY
TRACT OR MUCOUS MEMBRANE. DERMATITIS. COUGHING. NAUSEA. DIZZINESS.
HEADACHE.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL: REMOVE TO FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP.
GIVE O*2 IF BRTHG DFCLT. CALL MD. SKIN: FLUSH W/COPIOUS AMT OF
WATER. EYES: FLUSH IMMED W/PLENTY WATER FOR @ LEAST 15 MIN. CALL
MD. INGEST: DO NOT INDUCE VOMIT. GIVE LG QTY WATER. NEVER GIVE
ANYTHING BY MOUTH TO UNCON PERSON. CALL MD. REFER ALL CASES OF
INGEST TO POIS CTL CTR/MD. VOMIT SHOULD NORM BE INITIATED ONLY ON
THEIR ADVICE (SUPDAT)

Fire Fighting

Flash Point:NONE
Extinguishing Media:THIS PRODUCT IS NON-COMBUSTIBLE. USE EXTINGUISHING
MEDIA APPLICABLE TO THE PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . EVACUATE PERSONNEL TO A SAFE AREA REMOVED
AND UPWIND OF THE FIRE.
Unusual Fire/Explosion Hazard:FIRE OR EXCESSIVE HEAT MIGHT CAUSE
PRODUCTION OF HAZARDOUS DECOMPOSITION PRODUCTS.

Accidental Release

Spill Release Procedures:CONTAIN THE SPILL. NEUTRALIZE WITH SODIUM
BICARBONATE. IF LOCAL EFFLUENT LAWS PERMIT, FLUSH TO SEWER WITH
LARGE AMOUNTS OF WATER.
Neutralizing Agent:SODIUM BICARBONATE.

Handling

Handling and Storage Precautions:KEEP CONTAINER TIGHTLY CLOSED WHEN NOT
IN USE. DO NOT STORE/CONSUME FOOD, DRINKS/TOBACCO IN AREAS WHERE
THEY MIGHT BE CONTAMINATED BY THIS PRODUCT.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE
FOR EXPOSURE OF CONCERN .
Ventilation:GOOD GENERAL VENTILATION (10 ROOM VOLUMES PER HOUR) SHOULD
BE SUFFICIENT.
Protective Gloves:RUBBER OR PLASTIC GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKER GOGGLES .
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC: & BY MEANS THEY SPECIFY.

Chemical Properties

Boiling Pt:B.P. Text:>212F,>100C
Spec Gravity:1.13 (H*2O=1)
pH:10.1
Solubility in Water:100%
Appearance and Odor:STRAW COLORED, CLEAR LIQUID; NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:SULFUR DIOXIDE.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FED, STATE & LOCAL REGS .
IF PERMITTED, FLUSH TO SEWER W/LARGE AMOUNTS OF WATER. PRETREATMENT
MAY BE REQUIRED, OR DISPOSE OF IN AN APPRVD & PERMITTED BIOLOGICAL
TREATMENT SYSTEM OR APPRVD & PERMITTED DEEPWELL OR LANDFILL.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.